Single pair/multipair Overall Screen with Armor
Application
These cables are used in thermocouple circuits, petrochemical plants, utilities and industrial plants.
Specification
Conductor: Solid Type applicable: KX, EX, JX, TX, NX, KCA, KCB, RCA, RCB, SCA, RCB, BC
Insulation: PVC, PE, XLPE or LSZH thermoplastic material
Wrapping: At least 1 layer of plastic tape
Overall screen: 24 μm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Bedding: PE, PVC or LSZH thermoplastic material
Armor: Galvanized round steel wires
Outer sheath: PVC or LSZH thermoplastic material
Color code: According to IEC 60584-3
Flame retardancy: IEC 60332-1
Flame propagation: IEC 60332 cat. C
Temperature range: -30°C up to 70°C during operation. -5°C up to 50°C during installation.
0.5 mm²
Conductor Size | No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
0.5 | 1 | 0.4 | 0.8 | 0.9 | 1.3 | 9.6 | 206 |
0.5 | 2 | 0.4 | 0.8 | 0.9 | 1.4 | 12.1 | 295 |
0.5 | 4 | 0.4 | 0.9 | 0.9 | 1.4 | 13.4 | 374 |
0.5 | 6 | 0.4 | 1.1 | 0.9 | 1.4 | 15.4 | 480 |
0.5 | 8 | 0.4 | 1.1 | 0.9 | 1.5 | 16.3 | 546 |
0.5 | 10 | 0.4 | 1.2 | 0.9 | 1.5 | 17.9 | 656 |
0.5 | 12 | 0.4 | 1.2 | 0.9 | 1.5 | 18.5 | 703 |
0.5 | 16 | 0.4 | 1.2 | 1.25 | 1.6 | 21.1 | 975 |
0.5 | 20 | 0.4 | 1.2 | 1.25 | 1.6 | 22.5 | 1093 |
0.5 | 24 | 0.4 | 1.3 | 1.25 | 1.7 | 24.3 | 1285 |
0.8 mm²
Conductor Size | No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
0.8 | 1 | 0.4 | 0.8 | 0.9 | 1.3 | 10.0 | 227 |
0.8 | 2 | 0.4 | 0.9 | 0.9 | 1.4 | 13.0 | 343 |
0.8 | 4 | 0.4 | 0.9 | 0.9 | 1.4 | 14.3 | 431 |
0.8 | 6 | 0.4 | 1.1 | 0.9 | 1.5 | 16.7 | 567 |
0.8 | 8 | 0.4 | 1.2 | 0.9 | 1.5 | 17.6 | 657 |
0.8 | 10 | 0.4 | 1.2 | 0.9 | 1.6 | 19.4 | 788 |
0.8 | 12 | 0.4 | 1.2 | 1.25 | 1.6 | 20.8 | 999 |
0.8 | 16 | 0.4 | 1.2 | 1.25 | 1.7 | 22.9 | 1175 |
0.8 | 20 | 0.4 | 1.3 | 1.25 | 1.7 | 24.8 | 1347 |
0.8 | 24 | 0.4 | 1.3 | 1.25 | 1.7 | 26.3 | 1556 |
1.0 mm²
Conductor Size | No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
1.0 | 1 | 0.4 | 0.8 | 0.9 | 1.3 | 10.3 | 240 |
1.0 | 2 | 0.4 | 0.9 | 0.9 | 1.4 | 13.4 | 366 |
1.0 | 4 | 0.4 | 1.1 | 0.9 | 1.4 | 15.1 | 489 |
1.0 | 6 | 0.4 | 1.2 | 0.9 | 1.5 | 17.4 | 629 |
1.0 | 8 | 0.4 | 1.2 | 0.9 | 1.5 | 18.2 | 720 |
1.0 | 10 | 0.4 | 1.2 | 1.25 | 1.6 | 20.9 | 1016 |
1.0 | 12 | 0.4 | 1.2 | 1.25 | 1.6 | 21.5 | 1094 |
1.0 | 16 | 0.4 | 1.3 | 1.25 | 1.7 | 24.0 | 1312 |
1.0 | 20 | 0.4 | 1.3 | 1.25 | 1.7 | 25.7 | 1490 |
1.0 | 24 | 0.4 | 1.3 | 1.25 | 1.7 | 27.3 | 1727 |
1.3 mm²
Conductor Size | No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
1.3 | 1 | 0.4 | 0.8 | 0.9 | 1.3 | 10.6 | 258 |
1.3 | 2 | 0.4 | 0.9 | 0.9 | 1.4 | 14.6 | 399 |
1.3 | 4 | 0.4 | 1.1 | 0.9 | 1.5 | 16.8 | 546 |
1.3 | 6 | 0.4 | 1.2 | 0.9 | 1.5 | 19.3 | 701 |
1.3 | 8 | 0.4 | 1.2 | 0.9 | 1.6 | 20.4 | 817 |
1.3 | 10 | 0.4 | 1.2 | 1.25 | 1.6 | 23.2 | 1136 |
1.3 | 12 | 0.4 | 1.2 | 1.25 | 1.7 | 24.2 | 1240 |
1.3 | 16 | 0.4 | 1.3 | 1.25 | 1.7 | 26.8 | 1484 |
1.3 | 20 | 0.4 | 1.3 | 1.25 | 1.7 | 28.9 | 1697 |
1.3 | 24 | 0.4 | 1.5 | 1.25 | 1.8 | 31.5 | 2025 |
1.5 mm²
Conductor Size | No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
1.5 | 1 | 0.5 | 0.8 | 0.9 | 1.3 | 11.2 | 284 |
1.5 | 2 | 0.5 | 1.1 | 0.9 | 1.4 | 16.1 | 467 |
1.5 | 4 | 0.5 | 1.2 | 0.9 | 1.5 | 18.3 | 627 |
1.5 | 6 | 0.5 | 1.2 | 0.9 | 1.6 | 21.2 | 802 |
1.5 | 8 | 0.5 | 1.2 | 1.25 | 1.6 | 22.9 | 1082 |
1.5 | 10 | 0.5 | 1.3 | 1.25 | 1.7 | 25.7 | 1319 |
1.5 | 12 | 0.5 | 1.3 | 1.25 | 1.7 | 26.6 | 1430 |
1.5 | 16 | 0.5 | 1.3 | 1.25 | 1.7 | 29.3 | 1697 |
1.5 | 20 | 0.5 | 1.5 | 1.25 | 1.8 | 32.4 | 2000 |
1.5 | 24 | 0.5 | 1.5 | 1.6 | 1.9 | 35.5 | 2598 |
*The number here is just approx. weight. It changes according to the insulation material and the conductor used in different type of extension cable and compensating cable.